Specifications

Chapter 3 Operation Installation and Operation Manual
3-6 Configuration and Management Alternatives Optimux-108 Ver. 6.1
³ To start a terminal control session:
1. Make sure all Optimux-108 cables and connectors are properly connected.
2. Connect Optimux-108 to a PC equipped with an ASCII terminal emulation
application (for example, Windows Hyper Terminal or Procomm).
3. Turn on the control terminal PC and set its port parameters to 115,200 baud,
8 bits/character, 1 stop bit, no parity, flow control: none.
4. Set the terminal emulator to VT100 emulation (for optimal view of system
menus).
5. If you are using Hyper Terminal, set the terminal application under windows
system to 132-column mode for optimal view of system menus (Properties >
Settings > Terminal Setup > 132 column mode).
6. When the initialization and self-test are over, press any key to display the
user name and password entry fields.
Login
To prevent unauthorized modification of the operating parameters, Optimux-108
supports two access levels:
Superuser can perform all the activities supported by the Optimux-108
management facility, including defining new users.
User’s access rights (full control or read only) are defined by the superuser.
Users are not allowed to create new users.
1. After the SW finishes uploading, press Enter a few times.
"..." appears.
2. Press <.> a few times until the following Password Prompt screen appears.
(This synchronizes the baud rate of the terminal to the setup configuration).
Optimux-108
USER NAME: SU
PASSWORD: ****
ESC - clear; & - exit; 0 M/ 1 C
Figure
3-3. Password Prompt Screen
It is recommended to change default passwords to prevent unauthorized access
to the unit.
³ To enter as a superuser:
1. Enter su for user name.
2. Enter 1234 for password.
This allows you to configure all the parameters of Optimux-108, and to change
the
su and user passwords.
Note