Specifications

Installation and Operation Manual Chapter 3 Operation
Optimux-108 Ver. 6.1 Default Settings 3-3
Table
3-2. Optimux-108 Rear Panel Indicators
LED Function Color Meaning
USER ETH: LINK/ACT
Yellow On - USER link is up
Blinking yellow USER link is up and Rx and/or Tx frames are
being transmitted
Yellow Off – Management link is down
USER ETH: 100 Green On – 100M mode
Off – 10M mode
MNG ETH: LINK/ACT Yellow On - Management link is up
Blinking yellow Management link is up and Rx and/or Tx frames
are being transmitted
Yellow Off – Management link is down
MNG. ETH: 100 Green On – 100M mode
Off – 10M mode
SIG (located on the bottom
of the fiber optic module)
Green On – Signal is detected on fiber optic module
Off – signal not detected
3.3 Default Settings
Table
3-3
lists the default settings of the Optimux-108 configuration parameters.
Table
3-3. Default Settings
Type Parameter Default Value
System
Device Information
Name Optimux-108
Location The Location of the Device
Contact Person Name of Contact Person
Host
IP address 0.0.0.0
IP mask 0.0.0.0
Default gateway 0.0.0.0
Read Community public
Write Community private
Trap Community public
Management Access
Telnet All
SNMP All
Web All