Specifications

Chapter 2 Installation and Setup Installation and Operation Manual
2-2 Mounting the Unit Optimux-108 Ver. 6.1
2.2 Package Contents
The Optimux-108 package contains the following items:
One Optimux-108 unit
AC power cable (two cables when ordered with redundant power supply)
DC adapter plug (two plugs when ordered with redundant power supply))
Technical Documentation CD
Contro
l port cable: CBL-MUSB-DB9F
Alarm port cable: CBL-RJ45-DB9/F
V.35 interface cable (if V.35 interface is ordered):
CBL-AMP-M34 - Smart Serial to M34 interface
CBL-AMP-DB25-ISO2110 - Smart Serial to ISO 2110 interface
CBL-AMP-DB25-TLBS - Smart Serial to Telebras interface
RM-33-2 rack-mount kit (if ordered)
RM-35 or WM-35 rack mount kits for the metal enclosure unit (if ordered).
2.3 Required Equipment
The following equipment is required to install Optimux-108:
Fiber optic cables (for optical uplink interface)
RJ-45 E1 connector cables (for balanced tributary interface)
RJ-45 Ethernet connector cable category 5
Philips screwdriver (for installation in 19-inch rack).
2.4 Mounting the Unit
Optimux-108 is designed for installation as a desktop unit. It can also be
mounted in a 19" rack. For rack mounting instructions, refer to the RM-33-2
installation kit manual that comes with the RM kit for plastic enclosure unit and
RM-35 or WM-35 rack mount kits for the metal enclosure unit.
If Optimux-108 is to be used as a desktop unit, place and secure the unit on a
stable, non-movable surface.
Refer to the clearance and temperature requirements in
Site Requirements and
Prerequisites
.