Specifications
Installation and Operation Manual Chapter 1 Introduction
Optimux-108 Ver. 6.1 Technical Specifications 1-9
Management
Optimux-108 can be configured and monitored locally via an ASCII terminal, or
remotely via Telnet, Web-based remote access terminal (ConfiguRAD) or
RADview-TDM running in a Windows or Unix environment.
Power
The power supply is a wide-range AC/DC power supply that can be connected to
either an AC power source (100 to 240 VAC), or to a DC power source
(–48 VDC).
Optimux-108 can be ordered with one or two power supplies. When two power
supplies are installed, they share the load. If one of the power supplies fails or its
input power is disconnected, the other one continues providing power to the unit.
1.4 Technical Specifications
Uplink Interface
Number of Links
One or two (A and B)
Type
Fiber Optic
Performance
Refer to
Table
1-1
Connectors
ST, SC, FC/PC, or SC/PC, ordered option
(SF1/SF2 options only available with SC)
(SF3 option only available with SC/APC)
E1 Tributary
Interface
Applicable Standards
ITU-T Rec. G.703, G.823
Nominal Line Data Rate
2048 kbps
Line Code
HDB3
Bit Rate Tolerance
±25 ppm
Line Impedance
120Ω (balanced) or 75Ω (unbalanced)
Connectors
Balanced interface: Shielded RJ-45 connector
Unbalanced interface: two BNC coaxial connectors
Signal Levels
Transmit level
Balanced Interface
±3V ±10%
Unbalanced
Interface
±2.37V ±10%