Specifications

Optimux-108 Ver. 6.1 Configuring the Optimux-108 Units 7-1
Chapter 7
Configuring a Typical
Application
This chapter gives detailed instructions for configuring Optimux-108 for a typical
application.
A terminal can be used to configure a local Optimux-108. However, to configure
remote units, Telnet or SNMP is required.
Figure
7-1
illustrates a point-to-point
connection extended by a pair of Optimux-108 units.
Figure
7-1. Optimux-108 with V.35 port Point-to-Point Application
7.1 Configuring the Optimux-108 Units
³ To prepare a control session:
1. Connect all Optimux-108 connectors to the appropriate media.
2. Turn on the control terminal.
3. Configure the terminal to the default communication parameters:
115,200 baud, 8 bits/character, 1 stop bit, no parity, flow control: none.
4. Set the terminal emulator to VT100 emulation.
You are now ready to start a control session.