Specifications
Chapter 5 Monitoring and Diagnostics Installation and Operation Manual
5-12 Handling Events Optimux-108 Ver. 6.1
Table
5-8. Optimux-108 Alarms
Code Terminal Message Description Port Severity
1 PS A fail No voltage in power supply A. Major
2 PS B fail No voltage in power supply B. Major
3 Remote connection
FAIL
A managment connection could not be
established with the remote device.
Major
4 Redundancy not
available
Redundancy mode is set to AUTO or MANUAL
but the second link is not installed.
Major
30 ETH Integrity fail Failure in Ethernet management or Ethernet
user port integrity.
ETH-MNG
ETH
Major
31 Signal Loss Signal loss detected on uplinks or channels. E1
LINK
Major
32 Loss of Frame Frame loss detected on Uplink Major
27 DTE Failure (for V.35
option only)
DTE is not ready/connected (identified only if
ISO 2110 interface is connected to
Optimux-108).
V.35 Major
33 Rx AIS Received AIS on the channels. E1 Minor
Masking Alarms
You can configure whether various groups of alarms are trapped or not.
Optimux-108
Configuration>System>Alarms
1. Device Number > (Local)
2. Alarms (Unmasked)
3. Remote Connection Failed (Unmasked)
>
Please select item <1 to 3>
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s)
Figure
5-11. Alarm Menu
Table
5-9. Alarm Configuration Parameters
Parameter Possible Values Description
Device Number Local
Remote
Sets whether local or remote device is
to be masked or unmasked
Alarms Masked
Unmasked
Masked – The selected device alarms
are masked
Unmasked – The selected device
alarms are unmasked