Specifications

Chapter 5 Monitoring and Diagnostics Installation and Operation Manual
5-8 Handling Alarms Optimux-106 Ver. 6.1
Displaying System Alarms
Monitoring>System>Active Alarms
Source Description Severity Status
1 Local Dev Remote Connection Failed Major Unmasked
2 Local Dev Redundancy not available Major Unmasked
>
ESC-Previous menu; !-Main Menu; &-Exit; ?-Help 1 User(s)
Figure
5-8. Active Alarms Screen
Table
5-6. Active Alarm Screen Fields
Field Description
Source The source that generated the alarm. Can be one of the following:
Local Device – system level alarm
Local LINK <A,B> – alarm generated on local uplink
Remote LINK <number> – alarm generated on remote uplink
Local T1 <number> – alarm generated on local T1 port
Remote T1 <number> – alarm generated on remote T1 port
Local Ethernet Management – alarm generated on local Ethernet port
Remote Ethernet Management – alarm generated on remote Ethernet port
Description Description of the alarm
Severity Indicated the severity of the relevant alarm
MINOR- Minor alarm
MAJOR- Major alarm
Status Status of the alarm:
Masked – active alarm for which no trap is sent.
Unmasked – active alarm for which trap is sent.
The Optimux-106 system alarms are described in
Table
5-8
.
Configuring Alarms
You can configure whether various groups of alarms are trapped or not.
Configuration>System>Alarms
1. Device Number > (Local)
2. Alarms > (Unmasked)
3. Remote Connection Failed > (Unmasked)
>
Please select item <1 to 3>
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s)
Figure
5-9. Alarm Menu