Technical information
Megaplex-4100/4104
Version 4.0
464-401-05/13 (4.0) Page 13
RAD Data Communications Ltd. http://www.rad.com
International Headquarters: 24 Raoul Wallenberg Street, Tel Aviv 69719, Israel Tel: (972) 3-6458181 Fax: (972) 3-6498250 Email: market@rad.com
North American Headquarters: 900 Corporate Drive, Mahwah, NJ 07430 Tel: (201) 529-1100 Toll free 1-800-444-7234 Fax: (201) 529-5777 Email: market@radusa.com
Release Note
Subject Description Status
E1 CAS over SHDSL does not operate
with an odd number of timeslots in
ASMi-54C/N Modules.
Workaround: When working with E1
CAS, configure even number of
timeslots.
TRS 12221
Rate limitation is not supported in the
ASMi-54C/N/E1/ETH module.
Workaround: Set the rate limitation
parameter in the CPE or use ASMi-54C
module
TRS 11787
In 4W mode, ASMi-54C/ETH modules
do not support rates in the range of
17024 kbps to 18432 kbps.
TRS 12677
In a chassis equipped with CL.2/A
assembly, local cross-connect on
ASMI-54C/N module between the
physical E1 and the E1-I port does not
work.
Will be solved in the ver 4.00 GA
release
TRS 13661
M8E1/M8T1
Modules
HDLC ports of the M8E1, M8T1 and
M8SL modules cannot be bound to
E1-i/T1-i ports of CL-B.
Workaround: Bind the HDLC ports to
the E1-i/T1-i ports of CL-A.
TRS 11765
M16E1/M16T1
Modules
In the CL.2/DS0 assembly with
Megaplex-4104 chassis occasionally
errors are observed on E1/T1s
originating from the M16E1/M16T1
module
TRS 13612
Will be solved in the ver 4.00 GA
release
RV-EMS
After communication with the unit has
been lost and recovered, the DB
change flag in Agent view indicates as
if the DB was changed.
TRS 12678
Workaround: Perform “Read”
operation in RADview.
“Read“operations from [A] to [E] start
at [E.N] (N is the database number:
1…10), but always finish at [E.1]
TRS
13200
Local loop on VC-12/VT-1.5 for
E1-i/T1-i does not work
Workaround: Perform a loop on the
relevant E1-i/T1-i port.
TRS
13225