Technical information
Megaplex-4100/4104
Version 4.0
464-401-05/13 (4.0) Page 10
RAD Data Communications Ltd. http://www.rad.com
International Headquarters: 24 Raoul Wallenberg Street, Tel Aviv 69719, Israel Tel: (972) 3-6458181 Fax: (972) 3-6498250 Email: market@rad.com
North American Headquarters: 900 Corporate Drive, Mahwah, NJ 07430 Tel: (201) 529-1100 Toll free 1-800-444-7234 Fax: (201) 529-5777 Email: market@radusa.com
Release Note
Subject Description Status
QoS
MEP is not supported on flows
terminating on bridge ports
TRS 13655
After changing the “ethertype” value
for a port, the MEP enters into the
“fail” status and the Ethernet OAM&P
functionality stops working.
Workaround: Reconfigure the relevant
port and flows
TRS 13656
Clock Domain
When the SDH/SONET clock is used, all
the DS0 cross-connect services must
be locked to this clock.
Workaround: Use transparent E1/T1
over SDH/SONET for clock
transparency.
TRS 11739
Connecting/disconnecting the station
clock sometimes causes data errors in
services
TRS 13469
The following trap variables are
missing in the trap for
“clockDomainSystemSrcClockChange “
alarm:
• 2863.ifAlias
• rad.csmSourceQL
• rad.csmDomainLastSystemSrcClkS
witchReason
TRS 13475
Stopping to transmit SSM messages to
the Megaplex station port has no
effect on the station clock status: it
still displays the last quality value
TRS 13470
Transmitting an SSM message to the
Megaplex station port with “ST4”
quality results in displaying “SMC”
quality
TRS 13470