Specifications
Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual
4-16 Handling Alarms MPW-1 MP-4100 Ver. 2.0
Code Syntax Type Meaning
2123 V1/V2 PW LABEL DUPLICATED Error After assigning a label to a pseudowire using payload
format V1, do not assign the next label in sequence to a
pseudowire using payload format V2 (skip that label).
See details given for sanity error 2103
2124 PEER NOT ATTACHED TO PW Error User has created a peer without attaching it to any
pseudowire
2125 SLOT/PORT OF R.IFACE IS NOT
CONNECTED
Error You must specify a valid I/O slot and port number to the
specified router interface
2126 WRONG FAR END TYPE
ASSIGNED TO RDN CH
Error When redundancy is configured between two internal DS1
ports, all their physical layer parameters must be identical
(including the Far End Type)
2127 PW FAR END TYPE PER SLOT IS
NOT EQUAL
Error When signaling is enabled on the internal DS1 port
attached to a pseudowire, the Far End Type for all the
pseudowires terminated on the corresponding MPW-1
must a framed mode (either E1 or T1)
2128 PEER PARAMETERS ARE
DUPLICATED
Error Different peers must not have the same destination IP
address and the same Next Hop IP address (at least one
of these parameters must be different). Therefore, if it
necessary for several pseudowires to reach the same IP
address, create separate router interfaces. See also sanity
error 2118
2129 CAN’T CARRY MIXED ETH & PW
TRAFFIC
Error An Ethernet port on an I/O module cannot be a member
of a flow that carries Ethernet traffic and at the same
time, be a member of another flow that carries
pseudowire traffic
2130 TS NOT ASSIGNED TO ANY PW Warning The specified MPW-1 internal DS1 port is connected to
local module ports, but no pseudowire has been assigned
timeslots on the same port (the reverse situation is
detected by sanity error 2122).
You must specify timeslots to be connected to the
internal DS1 port
2131 PW CREATED BUT NOT
ASSIGNED
Error A pseudowire has been created, but the attachment
circuit was not assigned timeslots
2132 PW CAN’T SERVE AS
RECOVERED CLK
Error A pseudowire using the HDLCoPSN protocol cannot serve
as recovered clock source
4.3 Handling Alarms
Table
4-9
lists the specific alarm messages that may generated by
Megaplex-4100 for MPW-1 modules, and explains their interpretation. The
messages are listed in ascending order of their codes. For other alarm messages,
refer to the
Megaplex-4100 Installation and Operation Manual
.