Specifications

Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual
4-14 Detecting Configuration Errors MPW-1 MP-4100 Ver. 2.0
Code Syntax Type Meaning
2105 IP & NEXT HOP SAME FOR
STATIC ROUT
Error This message is generated after the specified static route
is updated, and indicates that the next hop IP address and
the destination IP address of the route are the same.
This is not allowed – the addresses must be different. If
the next hop IP address is not needed, leave the default
value, 0.0.0.0.
Note however that this error may also appear because the
default IP addresses (0.0.0.0) have not yet been changed
2106 STATIC ROUTE IP IS NOT
UNIQUE
Error This message, which is generated only after the specified
static route is updated, indicates that the route
destination IP address is already used in another static
route.
This is not allowed – only one static route may be defined
for any specific destination IP address.
Note however that this error may also appear because the
default IP addresses (0.0.0.0) have not yet been changed
2107 ROUTER IFACES CAN'T BE ON
SAME SUBNET
Error The IP addresses assigned to the router interfaces must
be in different IP subnets
2108 MORE THAN 16 PWS FOR
INTERNAL DS1
Error You are trying to connect too many pseudowires to the
same internal DS1 port (the maximum is 16 pseudowire
per port)
2110 ILLEGAL FAR END TYPE
CONFIGURATION
Error The pseudowire Far End Type parameter must match the
framing mode of the internal DS1 port supporting the
pseudowire:
Framed mode: select E1, T1 ESF, or T1 SF
Unframed mode: select UNFRAMED
2111 INTERNAL DS1 OF PW IS DOWN Error The internal DS1 port assigned to a pseudowire is
configured as Down. Change its administrative status to
Up
2112 PW ASSIGNMENT MISMATCH Warning When a pseudowire is created, it is necessary to assign it
timeslots on a specific internal DS1 port.
This message is generated only after the specified
pseudowire is created.
You can assign the timeslots during the configuration of
the pseudowire service parameters; in addition, connect
the same timeslots of the internal DS1 port to the
prescribed I/O or PDH port
2113 TOO MANY ROUTER
INTERFACES
Error You are trying to configure more than 6 router interfaces
on a MPW-1 module (MPW-1 supports a maximum of 6
router interfaces). Check and remove unused interfaces