Specifications
Installation and Operation Manual Chapter 4 Troubleshooting and Diagnostics
MPW-1 MP-4100 Ver. 2.0 Monitoring Performance 4-5
Parameter Description
Rx Unicast Frames Total number of good unicast frames received through the corresponding
Ethernet port
Rx Multicast Frames Total number of good multicast frames received through the corresponding
Ethernet port
Rx Broadcast Frames Total number of good broadcast frames received through the corresponding
Ethernet port
Rx 64 Octets Total number of 64-byte frames received through the corresponding Ethernet
port
Rx 65-127 Octets Total number of frames with size of 65 to 127 bytes received through the
corresponding Ethernet port
Rx 128-255 Octets Total number of frames with size of 128 to 255 bytes received through the
corresponding Ethernet port
Rx 256-511 Octets Total number of frames with size of 256 to 511 bytes received through the
corresponding Ethernet port
Rx 512-1023 Octets Total number of frames with size of 512 to 1023 bytes received through the
corresponding Ethernet port
Rx 1024-long Octets Total number of frames with size of 1024 up to 1600 bytes received through
the corresponding Ethernet port
Tx Total Frames Total number of good frames transmitted by the corresponding Ethernet port
Tx Total Octets Total number of data octets carried by all the good frames transmitted by the
corresponding Ethernet port
Tx Correct Frames Total number good frames transmitted by the corresponding Ethernet port
Tx Collisions Total number of collisions detected at the corresponding Ethernet port
Tx Unicast Frames Total number of good unicast frames transmitted by the corresponding
Ethernet port
Tx Multicast Frames Total number of good multicast frames transmitted by the corresponding
Ethernet port
Tx Broadcast Frames Total number of good broadcast frames transmitted by the corresponding
Ethernet port