Specifications
Installation and Operation Manual Quick Start Guide
MPW-1 MP-4100 Ver. 2.0 3
Configuring Ethernet Ports Physical Layer Parameters
For the supervision terminal, use the Configuration > Physical Layer > I/O screen.
Parameter Values Parameter Values
Port Number 1 to 3
All Ports
Auto Negotiation ENABLE
DISABLE
Administrative
Status
DOWN
UP
Max. Capability
Advertised
(autonegotiation
enabled)
10Mbps half duplex
10Mbps full duplex
100Mbps half duplex
100Mbps full duplex
Name Up to 32 alphanumeric
characters
Speed & Duplex
(autonegotiation
disabled)
10Mbps half duplex
10Mbps full duplex
100Mbps half duplex
100Mbps full duplex
Configuring the General Router Parameters
For the supervision terminal, use the Configuration > Applications > Router >
Interface screen.
Parameter Values
Default Gateway Valid IP address in the subnet of one of the router
interfaces, in dotted-quad notation
ARP Aging Time 300 to 1000000 sec
Configuring the Router Interfaces
For the supervision terminal, use the Configuration > Applications > Router
screen.
Parameter Values Parameter Values
Number 1 to 100 Slot I/O-1 to I/O-10
CL-A and CL-B
Name Up to 32 alphanumeric characters Port I/O modules with Ethernet ports: ETH
port (ETH-1, ETH-2 or ETH-3)
CL.1/GbE modules: GbE-1 and GbE-2
CL.1/155GbE modules: GbE-1, GbE-2,
and VCG1 to VCG8
IP address Valid IP address in dotted-quad
notation
VLAN Tagging DISABLE
ENABLE
IP Mask Valid IP subnet mask in dotted-quad
notation
VLAN ID 1 to 4094