Specifications

Chapter 3 Configuration Installation and Operation Manual
3-16 Configuring Pseudowire Services MPW-1 MP-4100 Ver. 2.0
Table
3-4. Router Parameters
Parameter Function Values
Interface Displays the router interface
configuration screen
See
Table
3-5
below
Static Route Displays the static route
configuration screen
See
Table
3-6
below
Default Gateway Specifies the default gateway IP
address (usually an IP router port) to
which the router will send packets
when other routing criteria are not
met (see
Figure
3-1
).
The default value, 0.0.0.0, means
that no default gateway is defined
Type the desired IP address, using the
dotted-quad format.
Make sure that the IP address is within the
subnet of one of the router interfaces.
Default: 0.0.0.0
ARP Aging Time
(sec)
Selects the aging time for ARP
entries.
If the ARP entry for a given
destination is not refreshed before
the specified interval expires, that
information is deleted from the ARP
table
The allowed range is 300 to 1000000 sec, in
16-sec increments.
If the entered value is not a multiple of 16, the
nearest multiple of 16 not exceeding your entry,
is actually used.
Default: 1200 (20 minutes)
Configuring Router Interfaces
You can configure a total of 100 router interfaces within the Megaplex-4100, but
not more than 6 interfaces per MPW-1 module.
³ To configure router interfaces:
1. Navigate to the Configuration > Applications > Router screen, and then select
Interface.
2. Select the desired interface index:
To modify an existing interface, enter its number in the Number field, or
scroll using F and B
To define a new interface, select Add. The new interface is automatically
assigned the next free number, in the range of 1 to 100.
3. To delete unnecessary interfaces, select Delete (you will be requested to
confirm).
Table
3-5
describes the router interface parameters.
Table
3-5. Router Interface Parameters
Parameter Function Values
Number Specifies the index number
representing the router interface
The allowed range is 1 to 100.
Default: 1