Specifications

Installation and Operation Manual Chapter 3 Configuration
MPW-1 MP-4100 Ver. 2.0 Putting a New MPW-1 Module in Service 3-9
Parameter Function Values
Redundant
Port
Selects the other port of a redundancy
pair.
The selection must always be
symmetrical.
This parameter is not displayed when
Redundancy is NONE
The available selections depend on the destination
module and the number of active ports on the other
module:
1 to 8 for external and internal E1 or T1 ports
1 to 8 for internal_DS1 ports
1 to 63 PDH ports on a CL module using STM-1
links.
1 to 84 for PDH ports on a CL module using OC-3
links.
Default: – (no port selected)
Wait to
Restore
Specifies the time following the last
redundancy switching (flipping) during
which alarms are ignored.
Therefore, the module starts
evaluating the criteria for redundancy
switching (flipping) only after this
interval expires. This ensures that
another flipping cannot occur before
the specified interval expires
The supported range is 0 to 999 seconds.
Default: 300
Cross Connect Selects the handling of the data
passing through the selected port
DS0 – Enables routing each individual timeslot from
this port to other module ports or pseudowires. This
mode is not supported when using the UNFRAMED
mode.
DS1 – In the UNFRAMED mode, the data stream
handled by this port is transparently connected to
another port or pseudowire.
In the FRAMED mode, only the payload timeslots are
transparently connected.
Default: DS0 for FRAMED mode.
DS1 for UNFRAMED mode
Destination
Slot
Specifies the module (I/O slot) to
which the data stream handled by the
selected port is routed.
This parameter is displayed only when
using the DS1 cross-connect mode
The available selections are the CL modules installed
in the chassis, and I/O modules IO-1 to IO-10.
Default: CL
Destination
Port
Specifies the port to which the data
stream handled by the selected port is
routed.
This parameter is displayed only when
using the DS1 cross-connect mode
The available selections depend on the destination
module and the number of active ports on the other
module:
1 to 8 for external and internal E1 or T1 ports
1 to 8 for internal_DS1 ports
1 to 63 PDH ports on a CL module using STM-1
links.
1 to 84 for PDH ports on a CL module using OC-3
links.
Default: – (no port selected)