Specifications
Installation and Operation Manual Chapter 3 Configuration
MPW-1 MP-4100 Ver. 2.0 Putting a New MPW-1 Module in Service 3-7
3.3 Putting a New MPW-1 Module in Service
Adding an MPW-1 to Megaplex-4100 Database
³ To program an MPW-1 module in the Megaplex-4100 database:
1. Navigate to the Configuration > System > Card Type screen.
2. Bring the cursor to the field of the prescribed I/O slot by clicking <Tab>, and
then select MPW-1.
3. Update the Megaplex-4100 database, to save the new selection (type %, and
then type y to confirm).
If the programmed module is not yet installed in the Megaplex-4100, it is normal
to get a warning message reporting a programmed/installed module mismatch.
Configuring the Internal DS1 Ports
MPW-1 supports up to 8 internal DS1 ports, each capable of handling 32
timeslots.
Configuring Physical Layer Parameters of Internal DS1 Ports
³ To configure the physical layer parameters for the MPW-1 internal DS1 ports:
1. Navigate to the Configuration > Physical Layer > I/O screen, and then select
the I/O slot of the desired MPW-1.
2. Select the Int DS1 option.
You will see the configuration screen for the first internal DS1 port (the
port with the lowest index number). Scroll using F and B to reach the
desired port, or use the Port Number field to enter manually the desired
port number, in the range of 1 to 8.
You will see the configuration screen for the selected internal DS1 port.
Table
3-2
lists the MPW-1 internal DS1 physical layer port parameters.
Table
3-2. Internal DS1 Port Physical Layer Parameters
Parameter Function Values
Port Number Selects the internal DS1 port to be
configured
Opens a port selection screen that displays the
available selections, 1 to 8.
Default: 1
Note