Specifications
Chapter 3 Configuration Installation and Operation Manual
3-6 Default Settings MPW-1 MP-4100 Ver. 2.0
Parameter Description Factory Default Value
OOS Signaling State of signaling bits sent to the internal DS1 port
connected to the selected pseudowire during
out-of-service periods
Forced idle
Attachment Circuit Parameters
Slot I/O slot number IO-1
Int-DS1 Number Internal DS1 port of the selected MPW-1 1
Time Slots Pseudowire timeslot assignment – (no timeslot assigned)
Recovered Clock Source Parameters
ID Recovered clock source index number 1
PW Number Pseudowire index number that will be the source with the
selected index number
The first index number
of an existing
pseudowire
Administrative Status Recovered clock source active or not Down
Source Quality Quality of original timing source Stratum 4
Network Type Type of packet switched network used to transport the
pseudowire
Type B