Specifications
MPW-1 MP-4100 Ver. 2.0 1
Quick Start Guide
If you are familiar with the MPW-1 modules, use this guide to prepare it for
operation.
SFPs installed on MPW-1 modules may be equipped with a laser diode. In such
cases, a label with the laser class and other warnings as applicable will be
attached near the optical transmitter. The laser warning symbol may be also
attached.
For your safety:
• Before turning on the equipment, make sure that the fiber optic cable is intact
and is connected to the optical transmitter.
• Do not use broken or unterminated fiber-optic cables/connectors.
• Do not look straight at the laser beam, and do not look directly into the
optical connectors while the module is operating.
• Do not attempt to adjust the laser drive current.
• The use of optical instruments with this product will increase eye hazard.
Laser power up to 1 mW could be collected by an optical instrument.
• Use of controls or adjustment or performing procedures other than those
specified herein may result in hazardous radiation exposure.
ATTENTION: The laser beam may be invisible!
Preparations for Operation
1. If necessary, install the prescribed SFPs in the MPW-1 SFP sockets.
2. Insert the module in the assigned I/O slot.
3. Refer to the site installation plan, identify the cables intended for connection
to the MPW-1 connectors, and connect the cables as explained below.
Connecting Cables to Ethernet Ports
³ To connect cables to the optical Ethernet ports:
1. Connect each prescribed cable to the corresponding MPW-1 connector, ETH1,
ETH2 or ETH3. When two fibers are used, pay attention to connector polarity:
the transmitter output is at left-hand side.
Connecting Cables to Electrical Ethernet Ports
³ To connect cables to the MPW-1 electrical Ethernet ports:
1. Connect the prescribed cable to the corresponding connector, ETH1, ETH2, or
ETH3.
Warning