Specifications

MPW-1 MP-4100 Ver. 2.0 1
Quick Start Guide
If you are familiar with the MPW-1 modules, use this guide to prepare it for
operation.
SFPs installed on MPW-1 modules may be equipped with a laser diode. In such
cases, a label with the laser class and other warnings as applicable will be
attached near the optical transmitter. The laser warning symbol may be also
attached.
For your safety:
Before turning on the equipment, make sure that the fiber optic cable is intact
and is connected to the optical transmitter.
Do not use broken or unterminated fiber-optic cables/connectors.
Do not look straight at the laser beam, and do not look directly into the
optical connectors while the module is operating.
Do not attempt to adjust the laser drive current.
The use of optical instruments with this product will increase eye hazard.
Laser power up to 1 mW could be collected by an optical instrument.
Use of controls or adjustment or performing procedures other than those
specified herein may result in hazardous radiation exposure.
ATTENTION: The laser beam may be invisible!
Preparations for Operation
1. If necessary, install the prescribed SFPs in the MPW-1 SFP sockets.
2. Insert the module in the assigned I/O slot.
3. Refer to the site installation plan, identify the cables intended for connection
to the MPW-1 connectors, and connect the cables as explained below.
Connecting Cables to Ethernet Ports
³ To connect cables to the optical Ethernet ports:
1. Connect each prescribed cable to the corresponding MPW-1 connector, ETH1,
ETH2 or ETH3. When two fibers are used, pay attention to connector polarity:
the transmitter output is at left-hand side.
Connecting Cables to Electrical Ethernet Ports
³ To connect cables to the MPW-1 electrical Ethernet ports:
1. Connect the prescribed cable to the corresponding connector, ETH1, ETH2, or
ETH3.
Warning