Specifications
Chapter 3 Configuration Installation and Operation Manual
3-2 Normal Indications MPW-1 MP-4100 Ver. 2.0
1. For framed internal DS1 ports using the DS0 cross-connect mode:
configure the utilization of the individual timeslots, including timeslots
using split assignment, for each module port. You can assign timeslots
only to ports already configured with Administrative Status set to Up.
For MPW-1 internal DS1 ports using the DS1 cross-connect mode, the connection
to another port is configured as part of the port physical layer parameters.
For the supervision terminal, use Configuration > Physical Layer > I/O >
TS Assignment, or Configuration > System > TS Assignment.
2. For internal DS1 ports that connect to PDH ports on a CL module with
STM-1 or OC-3 links (CL.1/155 or CL.1/155GbE): configure the
corresponding PDH port with compatible parameters (in particular,
configure a compatible framing mode), and then map the PDH port to the
prescribed TU of the specified SDH port.
For the supervision terminal, use Configuration > Logical Ports > CL, and
Configuration > System > Mapping, respectively (for instructions, refer to
the
Megaplex-4100 Installation and Operation Manual
).
³ To configure pseudowire services on the module (see
Section
3.4
):
1. Configure MPW-1 router parameters (interfaces, associated static routes,
default gateway, and ARP aging time).
For the supervision terminal, use Configuration > Applications > Router.
2. Configure the pseudowire peers (destinations).
For the supervision terminal, use Configuration > Applications > Multi-Service
over PSN > Peers.
3. Configure the pseudowires terminated at the MPW-1 internal DS1 ports.
For the supervision terminal, use Configuration > Applications > Multi-Service
over PSN > PW.
4. If necessary, configure fault propagation for the relevant MPW-1
pseudowires.
For the supervision terminal, use Configuration > System > Fault Propagation
(for additional instructions, refer to the
Megaplex-4100 Installation and
Operation Manual
).
³ To configure pseudowires as system timing reference (see
Section
3.5
):
1. When necessary, modify the system timing reference to use the recovered
clock of an MPW-1 pseudowire as timing reference.
For the supervision terminal, use Configuration > System > Clock Source (for
additional information, see also the
Megaplex-4100 Installation and
Operation Manual
).
Note