Specifications
Installation and Operation Manual Chapter 2 Installation
MPW-1 MP-4100 Ver. 2.0 Installing the Module 2-3
To install the SFP:
1. Lock the latch wire of the SFP module by lifting it up until it clicks into place,
as illustrated in
Figure
2-1
.
Some SFP models have a plastic door instead of a latch wire.
Figure
2-1. Locking the Latch Wire of a
Typical SFP
2. Carefully remove the dust covers from the corresponding SFP socket of the
MPW-1 module, and from the SFP electrical connector.
3. Orient the SFP as shown in
Figure
2-1
, and then insert the rear end of the
SFP into the module socket.
4. Push SFP slowly backwards to mate the connectors, until the SFP clicks into
place. If you feel resistance before the connectors are fully mated, retract the
SFP using the latch wire as a pulling handle, and then repeat the procedure.
5. If necessary, repeat the procedure for the other SFP(s).
Replacing an SFP
SFPs can be hot-swapped. It is always recommended to coordinate SFP
replacement with the system administrator. Note that during the replacement of
SFPs, only the traffic on the affected ETH link is disrupted (the other ETH link can
continue to carry traffic).
³ To replace an SFP:
1. If necessary, disconnect any cables connected to the SFP connectors.
2. Push down the SFP locking wire, and then pull the SFP out.
3. Reinstall protective covers on the SFP electrical and optical connectors.
4. Install the replacement SFP in accordance with the
Installing an SFP
section.
Module Installation Procedure
The MPW-1 module starts operating as soon as it is inserted in an operating
chassis.
³ To install an MPW-1 module:
1. Refer to the system installation plan and identify the prescribed module slot.
2. Check that the fastening screws at the module sides are free to move.
Note
Warning