Specifications
Quick Start Guide Installation and Operation Manual
6 MPW-1 MP-4100 Ver. 2.0
Configuring Attachment Circuit Parameters
For the supervision terminal, use the Configuration > Applications >
Multi-Service over PSN > PW > Service Parameters > Attachment Circuit screen.
Parameter Values
Slot IO-1 to IO-10
Int DS1 Number 1 to 8
Time Slots See below
Selecting Timeslots Connected to a Pseudowire
For each pseudowire connected to an internal DS1 port using the DS0
cross-connect mode, configure timeslot assignment.
For the supervision terminal, use the Configuration > Applications >
Multi-Service over PSN > PW > Service Parameters > Time Slots screen.
Configuring Pseudowires as System Timing References
1. For the supervision terminal, use the Configuration > System > Clock Source
> Recovered screen to specify the pseudowire that can be used as system
timing references.
Parameter Values Parameter Values
Slot I/O-1 to I/O-10 Administrative
Status
DOWN
UP
Type ADAPTIVE Source Quality STRATUM 1 (not supported)
STRATUM 2 (not supported)
STRATUM 3
STRATUM 3E
STRATUM 4
ID 1 to 20 Network Type Type B
Type A
PW Number 1 to 640
2. Use the Configuration > System > Clock Source screen to include the required
pseudowires as timing reference sources, in accordance with the information
appearing in the
Megaplex-4100 Installation and Operation Manual
.