Specifications

Installation and Operation Manual Appendix C I2C Interface Management
MiRICi-E3T3 Ver. 2.2 Parameters C-9
Index R/W Parameter
Length
Description
0x413 R/W 12 SysContact1 – SNMP string
0x414 R/W 12 SysContact2 – SNMP string
0x415 R/W 2 SysContact3 – SNMP string
0x416 R/W 12 SysName1 – SNMP string
0x417 R/W 12 SysName2 – SNMP string
0x418 R/W 2 SysName3 – SNMP string
0x419 R/W 12 SysLocation1 – SNMP string
0x41a R/W 12 SysLocation2 – SNMP string
0x41b R/W 2 SysLocation3 – SNMP string
Configuration Parameters
You can configure the following parameters:
TLB0 (T3 only), Transmit line build out
TXP and TXN signals ~225 feet of cable or full amplitude
Framed
Line code:
B3ZS or AMI for T3
Clock, Rx clock or internal clock
TRDI, Normal operation or send RDI alarm
Configuration parameters are detailed in
Table
C-3
.
Table
C-3. Configuration Parameters
Index R/W Parameter Length Description Default
0x517 R+W 1 FEAC loop code: (T3 only)
0 = Disable
1 = Enable
1 = Enable
0x519 R+W 1 Digit 0, TLB0 (T3 only) - Transmit
line build out:
0 = TXP and TXN full amplitude
1 = TXP and TXN signals ~225 feet
of cable
Digit 1, Framed/Unframed
0 = Unframed
1 = Framed
Digit 2, Line code:
0 = B3ZS (T3) or HDB3 (E3)
1 = AMI
E3: XXXX 000X
Digit 1 = 0, unframed
Digit 2 = 0, HDB3
Digit 3 = 0, Rx clock
Digit 7 = 1, Up
T3: XXXX 0011
Digit 0 = 1, ~225
feet of cable
Digit 1 = 1, framed
Digit 2 = 0, B3ZS
Digit 3 = 0, Rx clock
Digit 7 = 1, Up