Specifications
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics
MiRICi-E3T3 Ver. 2.2 Handling Alarms and Traps 6-5
6.3 Handling Alarms and Traps
MiRICi-E3T3 maintains a log file that can hold up to 100 events (system
messages). All events are time stamped and contain a severity indication. Refer
to
Table
6-3
for a list of events generated by MiRICi-E3T3.
Displaying Events
You can view the event log.
³ To access the log file:
• In the System menu, select Log File.
The Log File screen appears.
MiRICi-E3T3
Monitoring > System > Log File
Current Time: 12:15:42
Code Description Severity Time
3 LOS_ON: 1 00:00:00
1 LINK_UP: Ethernet Port 1 00:00:00
5 LOF_ON: 1 00:00:00
9 RDI_ON: 1 00:00:00
11 OOF_ON: 1 00:00:00
Clear Table
Figure
6-3. Log File Screen with Events
Table
6-3. Event List
Parameter Description
AIS_ON, AIS_OFF Alarm indication signal; alarm triggered (ON),
alarm turned off (OFF)
BPV_ON, BPV_OFF Bipolar violation encountered (ON), resolved (OFF)
CCV_ON, CCV_OFF C-bit coding violation encountered (ON), resolved (OFF)
EXZ_ON, EXZ_OFF Excessive zeroes encountered (ON), resolved (OFF)
LCV_ON, LCV_OFF Line coding violation encountered (ON), resolved (OFF)
LOF_ON, LOF_OFF Loss of frame encountered (ON), resolved (OFF)
LOS_ON, LOS_OFF Loss of Signal encountered (ON), resolved (OFF)