Specifications
Installation and Operation Manual Chapter 3 Configuration
HS-RN MP-2100/2104 Ver. 12.6, MP-4100 Ver. 2.0 3-5
Parameter Function Values
Clock Mode Used to control the clock mode in
the synchronous mode.
This parameter is displayed only
when operating in the synchronous
mode
The available selections are:
DCE The channel provides transmit and
receive clocks to the DTE.
EXT DCE The channel provides the receive clock
to the DTE, and accepts the transmit
clock from the DTE.
Default: DCE
Oper Mode Selects the operation mode
BI-DIR Bidirectional (regular) mode
UNI-BRD TX Unidirectional broadcast transmit
mode
UNI-BRD RX Unidirectional broadcast receive mode
BID-BRD RX Bidirectional broadcast receive mode
(MP-2100/2104 only)
Default: BI-DIR
ML Slot
(MP-2100/2104
only)
Selects the I/O slot number of the
destination main link module
• When using the BI-DIR, UNI-BRD RX or
BID-BRD RX modes, you can select the desired
I/O slot.
• When using the UNI-BRD TX mode, this field
automatically changes to BRD, to remind you that
the destination port must be selected using the
DEF TS command.
Default: IO-1
ML Channel
(MP-2100/2104
only)
Selects the number of the main link
port on the selected destination main
link module
• When using the BI-DIR, UNI-BRD RX or
BID-BRD RX modes, you can select the desired
external port number. The supported range
depends on the number of external ports
available on the main link module installed in the
slot selected by the ML Slot parameter.
• When using the UNI-BRD TX mode, this field
automatically changes to BRD, to remind you that
the destination port must be selected using the
DEF TS command.
Default: EX1
Link to Slot
(MP-4100 only)
Specifies the module (I/O slot) to
which the data stream handled by the
port is routed.
The available selections are the CL module installed
in the chassis, and I/O modules IO-1 to IO-10.
Link to Port
(MP-4100 only)
Specifies the port to which the data
stream handled by the port is routed.
The available selections are 1 to 8 for external ports,
or 1 to 63 (1 to 84) for internal (virtual) ports
(actual range depends on the destination module).