Specifications
Chapter 3 Configuration Installation and Operation Manual
3-4 HS-RN MP-2100/2104 Ver. 12.6, MP-4100 Ver. 2.0
Parameter Function Values
Rate Specifies the channel data rate.
Notes
: 1. When Encapsulation mode
is “Latency optimized”, only rates up
to 19.2 are supported and occupying
the full timeslot bandwidth. 2. The
rates marked by asterisk (*) are
supported in the HDLC model only.
The range of selections is as follows:
ASYNC mode: 0.6, 1.2, 2.4, 4.8, 7.2*, 9.6, 14.4*,
19.2, 28.8*, or 38.4 kbps.
SYNC mode: 0.6, 1.2, 2.4, 4.8, 7.2*, 9.6, 14.4*,
19.2, 28.8*, 38.4, 56, or 64 kbps.
Default: 0.6 kbps
CTS Used to control the state of the CTS
line
The available selections are:
ON The CTS line is continuously on.
RTS The CTS line tracks the state of the local RTS
line.
Default: ON
DCD & DSR Controls the end-to-end
transmission of the local DTR and
RTS lines to the remote DSR and
DCD lines, respectively
LOCAL End-to-end transmission disabled,
only local support available.
Always use this selection for data
rates exceeding 38.4 kbps.
END-TO-END End-to-end transmission enabled:
the state of the local RTS and DTR
lines are reflected by the remote
DCD and DSR line, respectively. Do
not use this selection for data
rates exceeding 38.4 kbps.
Default: LOCAL
Data Bits* Selects the number of data bits.
This parameter is displayed only
when operating in the asynchronous
mode
The available selections are 5, 6, 7, or 8 bits.
Default: 8 BITS (MP-4100), 5 BITS (MP-2100/2104)
Parity* Used to control the end-to-end
transfer of the parity bit.
This parameter is displayed only
when operating in the asynchronous
mode
The available selections are:
YES The parity bit is transparently transferred
end-to-end. This selection is relevant only
when the user’s equipment generates a
parity bit.
NO The parity bit is not transferred.
Default: NO
Stop Bits* Used to select the number of stop
bits.
This parameter is displayed only
when operating in the asynchronous
mode
The available selections are 1 or 2 bits.
Default: 1
*
When setting the Async Mode parameters, pay attention to the total character length calculated by the
formula: M=data bits + parity + 1 start bit + stop bits. This length can be set to 8,9,10, or 11. The numbers
out of this range are not supported.