Specifications
HS-RN MP-2100/2104 Ver. 12.6, MP-4100 Ver. 2.0 3-1
Chapter 3
Configuration
3.1 Introduction
This chapter provides configuration information for HS-RN modules installed in
the Megaplex-2100/2104 or Megaplex-4100 chassis. For general instructions and
additional configuration procedures, refer to the
Megaplex-2100/2104
Installation and Operation Manual
and
Megaplex-4100 Installation and Operation
Manual,
respectively
.
The configuration is performed by means of the management system used to
control the Megaplex unit:
• Supervision terminal or Telnet – refer to the
Megaplex-2100/2104 Installation
and Operation Manual
or
Megaplex-4100 Installation and Operation Manual
for instructions.
• Web browser – refer to the
Megaplex-4100 Installation and Operation Manual
for instructions.
• Network management system, e.g., the RADview network management
system – refer to the
RADview User's Manual
for instructions.
3.2 Configuration Sequence for the MP-2100/2104
Chassis
³ To configure an HS-RN module and put it into service:
1. Add an HS-RN module not yet installed in the Megaplex-2100/2104 chassis to
the database. This allows preconfiguring the module parameters, so that the
module will immediately start operating in the desired mode as soon as it is
installed in the enclosure. For the supervision terminal, use the DEF SYS
command.
2. Configure the HS-RN channel parameters:
To define the parameters of all the module channels on the supervision
terminal, type the command:
DEF CH SS *
To define the parameters of a desired channel on the supervision
terminal, type the command:
DEF CH SS CC