Specifications

Quick-Start Guide MP-2100 HS-R
Installation and Operation Manual
2
Configuration Procedure
Start HS-R configuration by entering the command:
DEF CH A:*<CR>
. The
configuration parameters and the allowed range of values are listed below.
Parameter
TDM Link
[systems with
CL.1 only]
ML Slot
[systems with
CL.2 only]
ML Channel
[systems with
CL.2 only]
Connect
Range of
Values
IO-1 to
IO-12
IO-1 to
IO-12
EX1 to
EX2
YES
NO
Parameter
Format Rate Operation Mode
Range of
Values
ASYNC
SYNC
Async: 0.6,
1.2, 2.4, 4.8,
9.6, 19.2, and
38.4 kbps
Sync: 0.6,
1.2, 2.4, 4.8,
9.6, 19.2,
38.4, 48, 56,
and 64 kbps
BIDIRECTIONAL
UNI-BRD TX
UNI-BRD RX
Parameter
Data
[Async only]
Parity
[Async only]
Stop Bits
[Async only]
Range of
Values
5 BITS
6 BITS
7 BITS
8 BITS
YES
NO
1
2
Parameter
CTS DCD & DSR Mode
[Sync only]
Range of
Values
ON
RTS
LOCAL
END-TO-END
DCE
EXT DCE
Assign the required timeslot to each connected channel. Use the
DEF TS A:B
command to assign timeslots, and the
DEF SPLIT TS A:B:C
command to assign
a fraction of a timeslot.