Specifications

MP-2100 HS-R Installation and Operation Manual Tests & Diagnostics
Alarm Messages 4-3
4.3 Alarm Messages
Table 4-1 lists the specific alarm messages generated by the HS-R module, specifies
their type, and explains their interpretation. The module generates additional
alarm messages, which are not specific to HS-R modules; these messages are
explained in the Megaplex-2100 System Installation and Operation Manual.
Table 4-1 HS-R Alarm Messages
Code Message Type Interpretation
021 MODULE WAS REMOVED Event The module has been taken out of its slot
022 MODULE WAS INSERTED Event The module has been inserted
023 MODULE RESET OCCURRED Event The module has been automatically reset
024 MODULE INIT ERROR/
HARDWARE FAILURE
Event Module initialization, performed upon turn-on or
module insertion, has failed, or a hardware malfunction
has been detected in this module. Remove the module,
and then plug it again after a few minutes. If problem
recurs, the module needs service
025 NOT PROGRAMMED MODULE State
(Minor)
The module that has been read from the Megaplex unit
is not programmed in the active data base. Change the
Megaplex unit configuration as required
026 PROGRAMMED/INSTALL
MODULE MISMATCH
Major The module that has been read from the Megaplex unit
does not match the module programmed in the active
data base. Check and reconfigure as required
031 COMMUNICATION FAILURE (MP) Event The CL module reported a temporary failure in the
communication with the HS-R module
211 SYNC LOSS Major Loss of input signal or loss of synchronization on a
channel