Specifications
MP-2100 HS-R Installation & Operation Manual Configuration Instructions
Configuration Procedure 3-3
Table 3-1 Module HS-R Channel Parameters (Cont.)
Parameter Description
CTS Used to control the state of the CTS line. The available selections are:
ON The CTS line is continuously on
RTS
The CTS line tracks the state of the local RTS line
Default: ON
DCD & DSR Controls end-to-end transmission of the local DTR and RTS lines to the remote DSR and
DCD lines:
LOCAL End-to-end transmission disabled
END-TO-END End-to-end transmission enabled
Default: LOCAL
Mode
Sync only
Used to control the clock mode in synchronous mode. The available selections are:
DCE The channel provides transmit and receive clocks to the DTE
EXT DCE
The channel provides the receive clock to the DTE, and accepts the transmit
clock from the DTE
Default: DCE
Timeslot Assignment
After performing the configuration of the individual module channels, it is
necessary to assign the required timeslot to each connected channel. Use the
DEF
TS A:B
command to assign full timeslots, and the
DEF SPLIT TS A:B:C
command to assign a fraction of a timeslot.
Perform manual timeslot assignment as explained in the Megaplex-2100 System
Installation and Operation Manual.