3-2 Configuration Procedure
Table 3-1 Module HS-R Channel Parameters (Cont.)
Parameter Description
Connect Determines whether the corresponding channel is connected to the main link:
YES The channel is connected
NO
The channel is disconnected. You can still program the desired parameters, so the
channel will be ready to operate when needed
Default: YES
Format Specifies the channel operating mode:
ASYNC Asynchronous mode
SYNC Synchronous mode
Default: ASYNC
Rate Specifies the channel data rate. The available selections are as follows:
Async mode: 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, or 38.4 kbps
Sync mode:
0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 48, 56,
or
64
kbps
Default: 0.6 KBPS
Operation
Mode
Selects the channel operation mode (refer to the Megaplex-2100 System Installation and
Operation Manual for details):
BI-DIR Bidirectional (regular) mode
UNI-BRD TX
Unidirectional broadcast transmit mode
UNI-BRD RX Unidirectional broadcast receive mode
BID-BRD RX not supported
Default: BI-DIR
Data
Async only
Used to select the number of data bits in asynchronous mode. The available selections are:
5, 6, 7, or 8 BITS
Default: 5 BITS
Parity
Async only
Used to control the transfer of the parity bit in asynchronous mode. The available selections
are:
YES
The parity bit is transparently transferred
NO The parity bit is not transferred
Default: NO
Stop Bits
Async only
Used to select the number of stop bits in asynchronous mode. The available selections are 1
or 2 bits