Chapter 3
Configuration Instructions
3.1 Introduction
This chapter provides information on the configuration parameters of the HS-R
modules.
The configuration activities required to select the desired values of these
parameters are performed by means of the management system used to control
the Megaplex unit.
The instructions appearing in this chapter assume you are familiar with the
management system being used: a supervision terminal or Telnet (covered by the
Megaplex-2100 System Installation and Operation Manual), or a network
management system, e.g., the RADview network management system (refer to the
RADview User's Manual for instructions).
3.2 Configuration Procedure
Table 3-1 explains the programmable channel parameters and their range of
values.
Table 3-1 Module HS-R Channel Parameters
Parameter Description
TDM Link
Systems with
CL.1 only
Selects the main link that will carry the data stream generated by this module. The main link
is specified by indicating the number of the I/O slot in which the desired main link module
is installed, followed by the module port.
Default: IO-1
ML Slot
Systems with
CL.2 only
Selects the I/O slot of the main link module to which the channels carried by the
corresponding HS-R channel is routed.
Default: IO-1
ML Channel
Systems with
CL.2 only
Selects the number of the external port (1 or 2) of the main link module selected by the
ML Slot parameter.
Default: EX1