System information

Chapter 1 Edit Configuration Mode RADview-PC/TDM Megaplex-2100/2104 User’s Manual
1-72 Port Level Configuration Operations
Parameter Possible Values / Remarks
Direction NA, Tx, Rx, Both, BcastSrc, BcastDst
Note: To remove Bi-directional Bypass between 2 ML ports (Direction=Both), you
need to remove both entries (one for each port).
To change the Bypass to Unidirectional, you need to change the direction of one ML
port and other ML port TS connections from Both to Rx.
TS Type NC, Data, Voice, Mng
If you configure Time Slot Assignment between two MTML cards/Ports with
Direction=Both, and decide to change/remove that Time Slot Assignment, it must
be done for both MTML cards.
To change the default entry of the Source TS or Bit (not connected):
In the Time Slots Table, select an entry in the table and click <Replace...>
The Replace TS dialog box appears.
Figure 1-58. Replace TS Dialog Box
Table 1-41. Replace TS Parameters
Parameter Possible Values / Remarks
TS Src Index number of the selected time slot. This parameter is read-only
T1 link: 1..24
E1 link: 1..31
Slot Destination card slot in the current MP-2100. Options depend on the type of the
selected port
None, IO-1..IO-12, Split.
Note