System information

RADview-PC/TDM Megaplex-2100/2104 User’s Manual Chapter 1 Edit Configuration Mode
Port Level Configuration Operations 1-67
Parameter Possible Values / Remarks
Analog Signaling For VC-6A cards:
Loop–Start
For VC-6AG cards (same for all card ports):
Loop–Start
For VC-8 (same for all card ports):
Loop–Start,
Wink Start
VC-16 cards (same for every adjacent 8 ports):
Loop–Start,
Ground–Start, Wink Start
Meter Rate For VC-6A/FXO, VC-6A/FXS cards:
When Signaling Profile=3, 3 Metering Pulse: 16
, 12 else NA
For VC-8/FXO, VC-8/FXS, VC-16/FXO, VC-16/FXS cards:
16
, 12
Note: Meter Rate is the same for all card ports. Some versions of VC–8/FXO, VC–16/FXO
cards do not support Meter Rate. An alarm is issued if 12 or 16 is selected.
E&M Type For VC-8/E&M, VC-16/E&M cards:
Type 1, Type 2, Type 3, SSDC5
Note: E&M Type is the same for every 4 adjacent ports (1..4, 5..8, 9..12, 13..16).
Signaling
Feedback
For VC-8/FXO, VC-16/FXO cards:
No
, Yes
Note: Signaling Feedback is the same for every 8 adjacent ports (1..8, 9..16).
Remote Type Only for VC-6A/4LB cards
LB
, PBX
Conversation
Time (min)
Only for VC-6A/4LB cards
2
, 3, 5, Unlimited
Link To Slot
IO-1..IO-12, NA
Note: Only slots containing ML cards are available for selection
Link To Port External-1..External-2, Internal-1, NA (when Link to Slot=NA)
Port ID
Port ID
Note: Exists only for cards that support V5.1. Enabled only when Connect=V.5.1.
VC-6 Destination Parameters
Table 1-37. Destination Parameters – VC–6
Parameter Possible Values / Remarks
Dest Connect
No, Yes
Dest Mux Mux ID
Enter an internal ID number for Mux, nor IP address or Mux name
Dest Slot Destination Slot
Unknown, IO-1.. IO-15
Dest Port Destination Port
Unknown, External-1.. External-12, Internal-1..Internal-12