System information
Chapter 1 Edit Configuration Mode RADview-PC/TDM Megaplex-2100/2104 User’s Manual
1-44 Card Level Configuration Operations
Table 1-21. Card Information Parameters
Parameter Possible Values / Remarks
Slot Slot in which the selected card is inserted
Card Type Type of the selected card
No. of External Ports Number of external ports in the selected card
No. of Internal Ports Number of internal ports in the selected card
Adding a New Card
The Add command allows you to program a new card configuration in an empty
slot in the Edit Configuration mode.
To add a new card to the configuration:
1. In the Edit Configuration mode, click an empty slot.
2. From the Configuration menu, select Add…
The New Card dialog box appears containing the number of the selected
slot and a list of all cards supported by the current Megaplex.
3. From the New Card list, select the required card type. If necessary, drag the
scroll bar to view other card names.
Only certain combinations of cards are allowed. A warning message is displayed
when the user attempts to add a card that will not work in conjunction with existing
cards.
ML (Main Link) cards work in conjunction with common logic cards.
For MP 2100:
Slots PS 1 and PS 2 can only contain PS cards.
Slots CL 1 and CL 2 can only contain CL cards.
Slots IO 1 to IO 12 can take all other types, including unknown.
For MP 2104:
Slot PS 1 can only contain a PS card.
Slot CL 1 can only contain a CL card.
Slots IO 1 to IO 5 can take all other types, including unknown.
For each MUX, only one ACM card can be used. More than one ACM card will
cause a sanity check error.
4. Click <Set>.
The selected card is added to all existing Edit Configurations.
The card types supported by the Megaplex and which model supports them are
listed in the following table. X indicates that the card is supported, -- indicates that
the card is not supported.
* indicates that the card is supported for Megaplex agent software versions
≥
8.XX.
Note
Note