System information

Chapter 1 Edit Configuration Mode RADview-PC/TDM Megaplex-2100/2104 User’s Manual
1-34 System Level Configuration Operations
Figure 1-35. Redundancy Table Dialog Box
Table 1-15. Redundancy Table Parameters
Parameter Possible Values / Remarks
Redundancy Mode Redundancy Mode for the card
Y Cable, Dual Cable Parallel Tx
Primary Slot Primary Slot for the card
NA, IO-1..IO-12
Primary Port Primary Port for the card
External-1..External-2, Internal-1, Bundle1..Bundle120
Note:
For ML-1/T1, ML-1/E1 cards: only external-1 is available
For MLML-H, HSH cards: only external-1 is available
Secondary Slot Secondary Slot for the card
NA, IO-1..IO-12
Secondary Port Secondary Port for the card
External-1..External-2, Internal-1, , Bundle1..Bundle120
Note:
For ML-1/T1, ML-1/E1 cards: only external-1 is available
For MLML-H, HSH cards: only external-1 is available
Recovery Time (sec) Recovery time in seconds
1..99
[Add…] To open the Add Redundancy Couple dialog box, click <Add…>. Select the
desired parameters and click <Set>.
[Change…] To open the Change Redundancy Couple dialog box, select a line in the table and
click <Change…>. Select the desired parameters and click <Set>.
[Remove] To remove a Redundancy Couple, select a line in the table and click <Remove>.