System information

RADview-PC/TDM Megaplex-2100/2104 User’s Manual Chapter 1 Edit Configuration Mode
System Level Configuration Operations 1-25
Click on the right mouse button to change the fields in the TS Data dialog box.
Figure 1-25. R2 Data – TS Data Tab Dialog Box
Table 1-11. R2 Data Parameters
Parameter Possible Values / Remarks
Signaling Profile The profile number selected in the Select Profile dialog box
1 to 5
General Tab
R2 Mode Auto: default value of timers will be used by R2, according to selected Country
Manual: user can change the value of R2 timers within the valid limits, specific to
each country
Country
ITU–T
, Korea, India, Brazil (continuous), Brazil (pulsed), Argentina, 7, 8, 9, 10
R2 Delay Eenables you to configure link as satellite or terrestrial. Seize acknowledge detect
timing is much shorter for terrestrial link than for satellite link (1-2 sec)
Terrestrial
, Satellite
Metering Indication Indicates which Bit will be used for Metering Indication
C Bit
, B Bit
Timers Tab
The parameters of the Timers Tab are Read-Write only when R2 Mode = Manual
Break-Make Ratio
(msec)
Break-Make Ratio of Pulse Duration
56–44, 64–36
, 80–20
Release Guard T2
(msec)
Release guard timing before going to idle
16..2000
Note