System information
RADview-PC/TDM Megaplex-2100/2104 User’s Manual Chapter 1 Edit Configuration Mode
System Level Configuration Operations 1-21
Saving the Flip DB
The Save Flip DB command saves the flip configuration as the temporary flip
configuration of the Megaplex, without activating it over the net.
To save the Flip configuration as the Megaplex's temporary flip configuration:
1. From the Configuration menu, select Net Update and Flip DB…
The Net Update Save Flip DB Confirmation Dialog Box appears.
2. Click <OK> to confirm the Net Update Save Flip DB.
If the sanity check detects errors, RADview aborts the Save Flip DB
process.
Figure 1-20. Net Update Save Flip DB Confirmation Dialog Box
Setting Signaling Profile Parameters
Megaplex main link ports can be configured to use either legacy CAS (with or
without signaling conversion) or the R2 protocol. Different profiles are used to
define the format of the signaling information.
To set signaling profile parameters:
1. From the Configuration menu, select Signaling Profile…
The Signaling Profile dialog box appears.
2. Configure the Type of Signaling Profile (Legacy or R2 CAS) for the desired
profiles.
3. Configure Legacy Data or R2 Data for selected profiles (described below) and
click <Set>.