System information
Chapter 1 Edit Configuration Mode RADview-PC/TDM Megaplex-2100/2104 User’s Manual
1-20 System Level Configuration Operations
Net Update
The Net Update command allows you to save the current Edit Configuration
and/or flip configuration to all Megaplexes in the net.
Figure 1-18. Net Update Submenu
Saving the Configuration
The Save Config command allows you to save the current Edit Configuration as
the Megaplex's temporary configuration without activating it over the net.
To save the current Edit Configuration as the Megaplex's temporary
configuration:
1. From the Configuration menu, select Net Update followed by Save Config...
The Net Update Save Config dialog box appears.
2. Configure desired parameters and click <Apply>.
If the sanity check is successful, the download proceeds and the selected
Edit Configuration is saved as the temporary configuration of the Megaplex
but not activated over the net.
If warnings appear, completion of the download process requires user
confirmation. If the sanity check detects errors, RADview aborts the
download process and displays the error message, “Sanity Check errors
encountered by NMS”. To view a list of detected errors, click
<View Errors>.
Figure 1-19. Net Update Save Config Dialog Box
Table 1-9. Net Update Save Config Parameters
Parameter Possible Values / Remarks
Configuration Id Configuration ID number of Edit Configuration that you want to save as the temporary
configuration.
Description Brief description of the selected Edit Configuration.
To abort the Save Config operation in process:
• Click <Abort>.