System information

Chapter 2 Agent Configuration Mode RADview-PC/TDM Megaplex-2100/2104 User’s Manual
Table 2-39. VC Cards Software Configuration Parameters
Parameter Possible Values / Remarks
Coding Law Alaw, Ulaw
Note: Coding Law is the same for all card ports.
Signaling Method No Signaling, RobbedBitMultiFrame, RobbedBitFrame, Ch Associated E1
Note: Options vary depending on card. Signaling Method is the same for all card ports. It
does not exist for MTVC-2 cards.
Signaling Profile 1, 2, 3, 3 Reverse-Polarity, 3 Metering–Pulse, 4,
NA (when Signaling Method=No Signaling)
Note: Only for VC-6 family cards. Options vary depending on card. Signaling Profile is the
same for all card ports.
Encoding Mode PCM, ADPCM
Note: Only for VC-6A family, VC-8, VC-16, VC-16A cards. Encoding Mode is the same for
all card ports.
Analog Signaling For VC-6A cards:
Loop–Start
For VC-6AG cards (same for all card ports):
Loop–Start
For VC-8 (same for all card ports):
Loop–Start
, Wink Start
VC-16 cards (same for every adjacent 8 ports):
Loop–Start, Ground–Start, Wink Start
Meter Rate For VC-6A/FXO, VC-6A/FXS cards:
When Signaling Profile=3, 3 Metering Pulse: 16, 12 else NA
For VC-8/FXO, VC-8/FXS, VC-16/FXO, VC-16/FXS cards:
16, 12
Note: Meter Rate is the same for all card ports. Some versions of VC–8/FXO, VC–16/FXO
cards do not support Meter Rate. An alarm is issued if 12 or 16 is selected.
E&M Type For VC-8/E&M, VC-16/E&M cards:
Type 1, Type 2, Type 3, SSDC5
Note: E&M Type is the same for every 4 adjacent ports (1..4, 5..8, 9..12, 13..16).
Signaling
Feedback
For VC-8/FXO, VC-16/FXO cards:
No, Yes
Note: Signaling Feedback is the same for every 8 adjacent ports (1..8, 9..16).
Remote Type Only for VC-6A/4LB cards.
LB
, PBX
Conversation
Time (min)
Only for VC-6A/4LB cards.
2, 3, 5, Unlimited
Link To Slot IO-1..IO-12, Multiple
Only slots containing ML cards are available for selection.
Link To Port External-1..External-2, Internal-1, Multiple (when Link to Slot=Multiple)
2-64 Agent Port Level Operations