System information

RADview-PC/TDM Megaplex-2100/2104 User’s Manual Chapter 2 Agent Configuration Mode
Figure 2-52. Software Configuration – VC Cards
Table 2-38. VC Cards Software Configuration Parameters
Parameter Possible Values / Remarks
Connect Indicates whether the port should be considered in any of the Megaplex algorithms.
No, Yes.
Interface For E&M, MTVC-2, VC-16A cards:
2WIRE, 4WIRE
For others:
2WIRE
Note: Interface is the same for all card ports except for VC-8, VC-16 and VC-16A cards
where it can be different for each port.
Tx Level (dBm) Transmit level in steps of 1 or 0.5 dBm
–17...8
Note: Tx Level value can be offset by a certain value if Offset 1 is selected in the System
Information dialog box.
Rx Level (dBm) Receive level in steps of 1 or 0.5 dBm
–23...2
Note: The Rx Level value can be offset by a certain value if Offset 1 is selected in the
System Information dialog box.
Agent Port Level Operations 2-63