System information

RADview-PC/TDM Megaplex-2100/2104 User’s Manual Chapter 2 Agent Configuration Mode
Table 2-28. <<SW Cfg Tab MTML2/T1 (Cont.)
Parameter Possible Values / Remarks
Rx Gain
Short Haul, Long Haul
OOS Signal State of the signaling bits when the link is in out-of-service (OOS) state.
Forced Idle - Signaling bits A and B are idle when the link is in out-of-service state. In
addition, if the line type is ESF, signaling bits C and D are also idle.
Forced Busy - Signaling bits A and B are busy when the link is in out-of-service state. In
addition, if the line type is ESF, signaling bits C and D are also busy.
Busy Idle - Signaling bits A and B are busy for 2.5 seconds, then become idle until the
out-of-service state ends. In addition, if the line type is ESF, signaling bits C and D are
idle for 2.5 seconds before switching to busy state.
Idle Busy - Signaling bits A and B are idle for 2.5 seconds, then become busy until the
out-of-service state ends. In addition, if the line type is ESF, signaling bits C and D are
busy for 2.5 seconds before switching to idle state.
Voice OOS (hex) Voice out-of-service code transmitted on voice time slots when the link is out-of-service.
This value must be the same for both ports. To change the code, type the required code
in the edit box.
00-FF (hexadecimal).
Data OOS (hex) Data out-of-service code transmitted on data time slots when the link is out-of-service.
This value must be the same for both ports. To change the code, type the required code
in the edit box.
00-FF (hexadecimal).
Inband Mng Identifier of inband management over the link
Off, FDL or TS0, Dedicated TS, Dedicated TS/PPP, Dedicated FR
Inband Mng Rate
(Kbps)
Data rate of the inband management. Options depend on Inband Mng
NA, 4, 64
Inband Mng Rout
Protocol
Protocol of Inband Mng. Options depend on Inband Mng
None, RIP2, Proprietary
Agent Port Level Operations 2-51