System information

RADview-PC/TDM Megaplex-2100/2104 User’s Manual Chapter 2 Agent Configuration Mode
To display attributes of masked alarms (Mask = Yes or Yes and Save) within
the selected level in the Alarm Attributes table:
1. In the Attributes group, select Mask.
If the selected level is All, all masked alarms appear in the Alarms
Attributes table.
If the selected level is System, only masked alarms whose Slot and Port are
NA appear in the Alarms Attributes table.
If the selected level is Card and ports, only masked alarms whose slot
matches the Level group’s Slot parameter appear in the Alarms Attributes
table.
If the selected level is Ports, only masked alarms whose slot matches the
Level group’s Slot and Port parameters appear in the Alarms Attributes
table.
2. Click <Apply>.
To display attributes of inverted alarms (Invert = Yes) within the selected level
in the Alarm Attributes table:
1. In the Attributes group, select Invert.
If the selected level is All, all inverted alarms appear in the Alarms
Attributes table.
If the selected level is System, only inverted alarms whose Slot and Port
are NA appear in the Alarms Attributes table.
If the selected level is Card and ports, only inverted alarms whose slot
matches the Level group’s Slot parameter appear in the Alarms Attributes
table.
If the selected level is Ports, only inverted alarms whose slot matches the
Level group’s Slot and Port parameters appear in the Alarms Attributes
table.
2. Click <Apply>.
To display attributes of filtered alarms (Filter = Yes) within the selected level
in the Alarm Attributes table:
1. In the Attributes group, select Filter.
If the selected level is All, all filtered alarms appear in the Alarms Attributes
table.
If the selected level is System, only filtered alarms whose Slot and Port are
NA appear in the Alarms Attributes table.
If the selected level is Card and ports, only filtered alarms whose slot
matches the Level group’s Slot parameter appear in the Alarms Attributes
table.
If the selected level is Ports, only filtered alarms whose slot matches the
Level group’s Slot and Port parameters appear in the Alarms Attributes
table.
Megaplex Level Fault Operations 2-35