System information
Chapter 1 Edit Configuration Mode RADview-PC/TDM Megaplex-2100/2104 User’s Manual
1-2 Preliminary Hardware Configuration
Management via LAN
In this application, the management station is connected to the device through an
Ethernet LAN and an MBE (Ethernet Elementary Bridge). If the MBE and the device
are located in the same subnet, the system will operate immediately upon
hardware connection with no need for further software configuration.
Figure 1-2 and Figure 1-3 show a sample management via LAN application.
RADview-PC
Management Station
SLIP
Megaplex
Ethernet
MBE
E1
Megaplex
Figure 1-2. Megaplex Management via LAN
RADview-PC
Management Station
Ethernet
E1
E1
DXC
DXC
Megaplex Megaplex
Local Remote
Figure 1-3. Megaplex or DXC Management via LAN
1.2 Preliminary Hardware Configuration
Basic Configuration Tasks (for the MP2100/2104)
Preliminary hardware configuration for the MP2100/2104 is performed using a
Terminal Emulation program.
When selecting parameters, click the <F> and <B> keys to move forward and
backwards among the possible values for the selected parameter. Click <Enter>
to make a selection and the spacebar to move on to the next parameter.
To initiate terminal operation with the MP2100/2104:
1. With the PS and CL cards in place, switch unit to ON.
2. On the active CL card, set the DIP/pin adjacent to the alarm LED to ON.
3. Double-click the Terminal's icon.