Table 2-6. Flip BD Net Events Parameters
Parameter Possible Values / Remarks
Event No. The net event code number. This number is unique for a particular type of event in the
whole net. This prevents usage of the same number by more than one type of event.
1 to 511
Enable
in the Enable column indicates that an entry is valid. To add or modify parameters of a
net event, click the Enable checkbox () on the right side of the dialog box. To
delete/cancel an entry, you must first remove the .
Event Type Type of event
Time, Interface Down
Note: You can enable only one Time Event per Day Type. Enabling more than one Time
Event per Day Type causes a failure when you try to save the Flip DB to the Megaplex (Flip
DB Update)
For Event Type=Time, you can set the following parameters:
Day Type The type of day as determined in the Flip DB Agenda
Full Workday, Partial Workday, Weekend.
Start Time Time at which RADview activates the event.
Note: Start Time must be before the End Time
End Time Time at which RADview deactivates the event.
For Event Type=Interface Down, you can set the following parameters:
Slot Slot in the Megaplex in which the selected net event occurs
IO-1 to IO-12
For MP-2104: IO-1 to IO-5
Port Port in the Megaplex in which the selected net event occurs
external-1 to external-12, internal-1 to internal-12, depending on the type of card
IN Delay (sec) Delay time between the reporting of a net event as ON and the actual occurrence of the
event: 1 to 999
OUT Delay (sec) Delay time between the reporting of a net event as OFF and the actual termination of
the event: 1 to 999
Decision Table
The Decision Table displays combinations of events that will cause RADview to
flip automatically to a specific configuration.
To display the Decision Table:
From the Configuration menu, select Flip DB followed by Decision Table…
The Flip DB Decision Table appears.
Each entry in the Flip DB Decision Table defines a combination of events that
cause a specific Flip DB action.
System Level Agent Operations 2-13