User`s manual
Chapter 4 Configuring a Flow-Based Point-To-Point Application Installation and Operation Manual
4-2 Configuration Sequence RV-EMS/NGN LA-210 Ver. 1.5
4.1 Configuring the ETX-202 and LA-210 Units
Before you can start managing LA-210 via SNMP, the ETX-202 units and LA-210’s
IP settings must be configured using a terminal application.
³ To configure LA-210 and ETX-202 units:
1. Connect a PC to the serial port of each unit and use a terminal application to
log on to the relevant unit.
2. Configure IP settings (Configuration>System>Host) and take a note of the IP
addresses you assign if they differ from the ones suggested in
Figure
4-1
.
You will have to specify the IP addresses when adding or updating the
corresponding item in the Network Element Browser or the SNMPc
Management Console as well.
3. Verify that management access via SNMP is enabled for LA-210
(Configuration>System>Management> Management Access).
4. Connect the units to each other and to the network.
5. Configure the units for the desired application.
4.2 Configuration Sequence
You must configure the following to deploy LA-210 and ETX-202 units in this
application:
• System parameters (host IP, default gateway, VLANs for management access)
• Flow Interface configurations
• Flows.
Table
4-1. System Configuration Summary
Device Host IP IP mask Default Gateway
LA-210 172.17.182.22 255.255.255.0 172.17.182.1
DSLAM 172.17.182.23 255.255.255.0 172.17.182.1
ETX-202 (Client) 172.17.182.24 255.255.255.0 172.17.182.1
ETX-202 (Server) 172.17.182.13 255.255.255.0 172.17.182.1