User`s manual

Chapter 3 Configuration Management User’s Manual
3-34 Setting the Operational Parameters RV-EMS/NGN LA-210
Table
3-14. Change Service Dialog
Parameter Possible Values / Remarks
Flow ID The ID of the flow that this service belongs to.
Read-only
Flow Name The name of the flow that this service belongs to.
Read-only
Service ID The ID of the service. Each flow is associated with three services.
1–3
Read-only
Performance Monitoring Enables/disables Performance Monitoring
Enable
Disable
Default: Disable
Priority Determines the P bit value sent inside this OAM message that originates from
this service.
0–7
Default: 0
Delay Threshold (msec)
Determines the delay threshold for the specified service.
1–1000
Default: 0
Delay Variation
Threshold (msec))
Determines the delay variation threshold for the specified service
1–1000
Default: 0
Configuring Bridge Parameters
In Bridge mode, an internal bridge can be defined that connects the LA-210 unit’s
ports. Configure the bridge to properly process the VLAN tags to maintain priority
of the data flows.
The bridge operates in transparent mode (learning is disabled) or filtered mode
(learning and filtering are enabled).
³ To verify that LA-210 operates in Bridge mode
1. In the LA-210 View window, select the System view.
2. On the menu bar, click Configuration > System Parameters.
The System Parameters dialog appears displaying the current mode.
³ To define bridge parameters
1. In the LA-210 View window, select the System view.
2. On the menu bar, click Configuration > Bridge.
The Bridge menu appears.