User`s manual
User’s Manual Chapter 7 Fault Management
RV-EMS/NGN LA-210 Managing the Event Reporting for OAM (CFM) 7-5
Parameter Possible Values / Remarks
Rising Threshold A value above this threshold within the sampling interval for the specified
counter will be considered a rising event.
For Frames Above Delay or Frames Above Delay Variation:
1–2147483647
For Frame Loss Ratio or Unavailability Ratio:
1E-3, 1E-4, 1E-5, 1E-6, 1E-7, 1E-8, 1E-9, 1E-10
Default: 1
Falling Threshold A value below this threshold within the sampling interval for the specified
counter will be considered a falling event.
For Frames Above Delay or Frames Above Delay Variation:
0–2147483647
For Frame Loss Ratio or Unavailability Ratio:
1E-3, 1E-4, 1E-5, 1E-6, 1E-7, 1E-8, 1E-9, 1E-10
Default: 1
Sample Type Delta
Absolute
Sampling Interval (sec) The interval in seconds above which the data is sampled and compared with the
rising and falling thresholds.
1–2147483647
Event Type The Event type sent out after passing the threshold.
None
History Log
Trap
History Log & Trap
Default: None
³ To edit a configuration:
1. In the Event Reporting Configurations list (
Figure
7-2
), select the desired
event reporting configuration and click <Change>.
The Change Event Reporting Configurations Services dialog appears with
parameters to edit.
2. Modify the available parameters as outlined in
Table
7-1
and then click <Set>.
³ To remove a configuration:
• In the Event Reporting Configurations list (
Figure
7-2
), select the desired
configuration and click <Remove>.
The selected configuration is removed from the list.
³ To update the Event Reporting Configurations list:
• In the Event Reporting Configurations list (
Figure
7-2
), click <Refresh>.