User`s manual

Chapter 6 Security Management User’s Manual
6-4 Configuring SNMP RV-EMS/NGN LA-210
Figure
6-1. Host Dialog Box
Table
6-1. Host Parameters
Parameter Possible Values / Remarks
IP Address The unit’s IP address (read-only).
Note: The IP address must be configured using the Terminal application.
IP Mask The subnet that the unit belongs to (read-only).
Note: The subnet mask must be configured using the Terminal application.
Default Gateway The default gateway (read-only).
Note: The default gateway must be configured using the Terminal application.
VLAN Tagging Enables specifying a VLAN ID and a VLAN priorty, for example to create a
dedicated management VLAN.
Checked (enabled)
Cleared (disabled)
Default: Cleared
VLAN ID Specifies the VLAN ID
1–4094
VLAN Priority Specifies the priority of that VLAN
0–7
6.3 Configuring SNMP
RADview allows you to view and modify SNMP settings; enabling you to specify
the management station(s) that can transmit or receive LA-210 traps. There may
be between one to ten management stations defined.
You cannot change the number of management stations, or the Manager IDs, but
you can change the IP address(es).