User`s manual

Chapter 5 Performance Management User’s Manual
5-2 Viewing System Statistics RV-EMS/NGN LA-210
5.1 Viewing System Statistics
RADview allows you to set the polling interval and view OAM (CFM) statistics for
the LA-210 system.
Polling the Agent
Polling the agent updates the LA-210 device status. You can execute either
manual or automatic polling of the LA-210 system. Device components are
automatically polled once every minute. However, you can also manually poll and
update the status of the components.
³ To manually poll the agent components:
1. In the LA-210 View window, select the system.
2. On the menu bar, click Configuration > Poll Agent.
The components are polled and their status is updated immediately.
Setting the Polling Interval
You can set the polling interval by selecting the time (in seconds) that will pass
between two successive statistics polls of LA-210 ports.
³ To set the polling interval:
1. In the View window, select the system.
2. On the menu bar, click Statistics > Polling Interval.
Figure
5-1. Polling Interval Dialog Box
3. Fill in the field, as described in
Table
5-1
.
4. Click <Set> to implement the changes.
The new polling interval is set after the dialog box is refreshed, and
affects all Statistics dialog boxes of all ports. When updating the polling
interval while other dialog boxes are open, the new polling range is
updated only after an automatic polling occurs or upon clicking Poll.