Specifications

Installation and Operation Manual Chapter 3 Operation
LA-210 Ver. 1.5 Configuration and Management Alternatives 3-13
Working with ConfiguRAD
ConfiguRAD is a Web-based remote access terminal management software. It
provides a user-friendly interface for configuring, collecting statistics and
performing diagnostic tests on the unit.
Web Browser Requirements
The following Web browsers can be used to access the LA-210 ConfiguRAD
supervision utility from any location using Internet protocols.
Internet Explorer version 6.0 and up, running on Windows™ 98, Windows™
2000, Windows™ XP
Netscape Communicator version 7.1 and up, running on Windows™ NT or Unix
Firefox version 1.0.4 and up
Mozilla version 1.4.3 and up.
Logging In
³ To log in via Web browser:
1. Connect the Ethernet port to the LAN.
2. Open the Web browser.
3. Disable any pop-up blocking software, such as Google Popup Blocker.
4. Enter the IP address of the LA-210 in the address field of the browser in the
following format: http://’IP address’ (‘IP address’ stands for the actual LA-210
IP address which has to be assigned via an ASCII terminal).
5. Press <Enter> to command the browser to connect.
6. After the opening window is displayed, click LOGIN.
7. In the Password Entry window, enter your user name (read/write user default
is su) and password (default is 1234).
The ConfiguRAD Main menu is displayed.
It is recommended to change default passwords to prevent unauthorized
access to the unit.
LA-210 allows six management sessions to be active simultaneously:
one network session (Telnet, ConfiguRAD, RADview-Lite) and one ASCII
terminal session.
If no user input is detected for 5 minutes during a ConfiguRAD session,
LA-210 automatically disconnects from the management station.
Note